TOOL · COMPATIBILITY CHECKER
Chemical × Plastic Compatibility Checker
Query 2,500 chemical–material combinations (2,497 manufacturer-referenced ratings · 3 explicitly labeled NR · No data). Every result displays test conditions, applicable resin grade, evidence tier, and a direct link to the source reference chart.
CAS 67-64-1 × ISO 1043: PP
Acetone × Polypropylene (PP)
Manufacturer Reference
No significant attack; suitable for continuous contact under stated conditions.
- Test Temperature
- 20 °C
- Concentration
- 100%
- Exposure Basis
- Continuous immersion
- Applicable Resin / Compound Grade
- Unreinforced PP homopolymer (PP-H) & copolymer (PP-C)
- Source Chart & Verification Reference
- Cole-Parmer / Thermo Scientific Chemical Compatibility Consensus ↗ — Thermo Scientific Nalgene Chemical Resistance Chart / Cole-Parmer Compatibility Database (Retrieved 2026-11-24)
Engineering Notes
No significant chemical attack at 20 °C; suitable for reagent bottles and transfer lines. Expect reduced resistance above 50 °C.
MATCHED SUPPLIER SOURCING
Source PP Virgin & Modified Resin Pellets on Made-in-China.com FEATURED COMPATIBILITY BRIEFS
High-Demand Chemical × Material Guides
Acetone × Polypropylene (PP) Full conditions, caveats & alternatives → Acetone × Polycarbonate (PC) Full conditions, caveats & alternatives → Ethanol × Polypropylene (PP) Full conditions, caveats & alternatives → Hydrochloric Acid (37%) × Polypropylene (PP) Compatibility Full conditions, caveats & alternatives → Hydrochloric Acid (37%) × PVDF Full conditions, caveats & alternatives → Sulfuric Acid (98%) × PTFE Full conditions, caveats & alternatives → Sodium Hydroxide (50% NaOH) × HDPE Full conditions, caveats & alternatives → Toluene × FKM (Viton) Fluoroelastomer Compatibility Full conditions, caveats & alternatives → NMP × PVDF (Battery Slurry Pitfall) Full conditions, caveats & alternatives → Hydrofluoric Acid (48% HF) × HDPE Full conditions, caveats & alternatives →
METHODOLOGY & EVIDENCE TIERS
Rating Scale & Data Provenance
| Grade | Engineering Interpretation |
|---|---|
| No significant attack; suitable for continuous contact under stated conditions. | |
| Minor effect; slight swelling or discoloration possible over prolonged exposure. | |
| Moderate effect; softening, swelling, or loss of mechanical strength. Limited service only. | |
| Severe attack, dissolution, cracking, or rapid degradation. Do not use in contact. | |
| No verified compatibility data available for this combination. |
| Evidence Tier | Meaning |
|---|---|
| Primary Test Data | Backed by direct ASTM D543 / ISO 175 immersion or gravimetric test reports. |
| Manufacturer Reference | Cross-referenced from published resin, piping, or seal manufacturer resistance charts. |
| No Data (NR) | No verified test or manufacturer chart record; never inferred or extrapolated. |
Source: Cole-Parmer, Thermo Scientific (Nalgene), GF Piping Systems & Parker O-Ring Handbook · Retrieved 2026-11-25